Euphonix ROBO-678 Specifikace

Procházejte online nebo si stáhněte Specifikace pro Barebones pro PC / pracovní stanice Euphonix ROBO-678. Euphonix ROBO-678 Specifications [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1

VOYAGE DATA RECORDERVR-5000(Serial number 1001 or greater)

Strany 2 - SAFETY INSTRUCTIONS

-1.1- Chapter 1 OPERATION 1.1 OVERVIEW The VR-5000 consists of Data Collecting Unit or DCU, Data Recording Unit or DRU, and bridge microphone units

Strany 3 - CAUTION AT POWER-ON

-1.2- non-halogen Firewire cable or IEEE1394. Data Collecting Unit The Data Collecting Unit (DCU) mainly consists of Data Processor Unit, Power Distri

Strany 4 - CONTENTS

-1.3- The microphones are labelled Mic1, Mic2, etc. Microphone captures conversation in the bridge, audio signals from equipment and sound from machin

Strany 5 - INTRODUCTION

-1.4- .13 Watertight and fire door status The DCU obtains the IMO mandatory watertight and fire door status signals. The inputs, digital or R

Strany 6 - SPECIFICATIONS

-1.5- 1.2 OPERATING PROCEDURE The VDR comes with three keys for the protection against any unauthorized access. The key must be kept securely after

Strany 7 - Physical data

-1.6- 1.3 OPERATION ON REMOTE ALARM PANEL No power switch is provided on the Remote alarm panel. It is turned on and off by the power switch on the D

Strany 8 - MANUFACTURER’S DECLARATION

-1.7- 1.4 LED STATUS The LEDs on the Power Distribution Unit (PDU) operates as follows. Table 1.1 Status of LEDs LEDs Status Remarks AC Green Pres

Strany 9 - SYSTEM CONFIGURATION

-1.8- The green LED (right) on the panel is “Power” indicator and the amber one (left) is HD access indicator. HD access indicator Front pan

Strany 10 - Chapter 1 OPERATION

-2.1- Chapter 2 MAINTENANCE Periodic checks and maintenance are important for proper operation of any electronic systems. This chapter contains main

Strany 11 - Data items to be recorded

-2.2- Note that the batteries should be recycled. Contact FURUNO dealer. To replace the batteries; .1 Open the front cover with the key. .2 Remove f

Strany 12

IWARNINGELECTRICAL SHOCK HAZARDDo not open the equipment.Only qualified personnelshould work inside theequipment.Do not disassemble or modify theequi

Strany 13

-2.3- 2.3 REPLACING ACOUSTIC BEACON The underwater acoustic beacon has a built-in battery with approx 6 year lifetime. The beacon must be replace

Strany 14 - 1.2 OPERATING PROCEDURE

-3.1- Chapter 3 TROUBLESHOOTING This chapter provides information on possible causes of problems you may experience with your VDR. If you still have

Strany 15 - REMOTE ALARM PANEL VR-5016

-3.2- 3.2 OPERATING STATUS The operating status is indicated by LEDs on the DCU. Table 3.2 shows red and orange LED status during normal operation of

Strany 16 - 1.4 LED STATUS

-3.3- SYS 1 SYS 2 SYS 3 DCU OK Code NameYELLOW YELLOW YELLOW GREEN253PRC_STATUS_OK_INDICATIONSYS 1 SYS 2 SYS 3 DCU OK Code NameYELLOW YELLOW YELLOW

Strany 17 - 1.6 HOW TO REMOVE DRU

-3.4- SYS 1 SYS 2 SYS 3 DCU OK Code NameOFF OFF RED RED130PRC_STATUS_DATAIO_FAILURE_INDICATION SYS 1 SYS 2 SYS 3 DCU OK Code NameRED RED OFF RED042P

Strany 18 - Chapter 2 MAINTENANCE

-3.5- SYS 1 SYS 2 SYS 3 DCU OK Code NameOFF RED RED RED 162 PRC_STATUS_CONFIG_MISSING_IN_FLASHSYS 1 SYS 2 SYS 3 DCU OK Code NameGREEN GREEN GREEN RED

Strany 19 - To replace the batteries;

-3.6- SYS 1 SYS 2 SYS 3 DCU OK Code NameGREEN GREEN YELLOW RED 214 PRC_STATUS_RUNNING_ON_BATTERYSYS 1 SYS 2 SYS 3 DCU OK Code NameGREEN YELLOW YELLO

Strany 20 - (VR-5021)

-4.1- Chapter 4 LOCATION OF PARTS *: To pull out the PDU, first pull out the DPU. Data Collecti

Strany 21 - Chapter 3 TROUBLESHOOTING

-4.2- Digital IF Board Frame Grabber Board (w/ Multiplexer) Analog IF Board Video Board Audio Analog Board

Strany 22 - 3.2 OPERATING STATUS

-4.3- DIGITAL AUDIO LED INTF 24 VDC ANALOG

Strany 23 - R-5000 error codes (3.0)

II CAUTION AT POWER-ON In the DCU, confirm that the LEDs SYS1, SYS2, and SYS3 light in orange and DCU OK in green after the power has been on two mi

Strany 24

-4.4- MAIN JB Board SUB JB Board Junction Box (JB), Rear view Capsule rleasing latches Underwater acoustic beacon (P

Strany 25

-4.5- VR-5000 PARTS LIST This equipment contains complex modules in which fault diagnosis and repair down to component level are not practical (IMO A.

Strany 26

-4.6- Module Ty p e Code No. Remarks Breaker III-FII2-PIMI-16A DC and BAT Breaker III-FII2-PIMI-3A AC Junction Box JB MAIN Board

Strany 27

-5.1- Chapter 5 SERIAL INTERFACE (IEC 61162-1) Notes: Some sentences described here are proposed ones by the recent IEC TC80/WG6 (Digital Interface

Strany 28

-5.2- FIR – Fire detection (PAS 102) 0 1 2 3 4 5 6 7 8 9 10 $xxFIR, A, hhmmss.ss, aa, xx, xxx, xxx, A, A, c--c

Strany 29 - VD4 from bottom)

-5.3- MWV - Wind speed and angle (PAS 102) When the reference field is set to relative, data is provided giving the wind angle in relation to th

Strany 30 -

-5.4- RMC – Recommended Minimum Specific GPS Data Checksum, mandatory for RMC Magnetic variation (000.0 - 180.0°), degr

Strany 31 - VR-5000 PARTS LIST

-5.5- VBW - Dual ground/water speed: This sentence to be expanded as shown below: $--VBW, x.x, x.x, A, x.x, x.x, A, x.x, A, x.x, A *hh<CR><L

Strany 32

-5.6- XDR - Transducer measurements Measurement data from transducers that measure physical quantities such as temperature, force, pressure, frequenc

Strany 34 - 0 1 2 3 4

IIICONTENTS INTRODUCTION...

Strany 35

The paper used in this manualis elemental chlorine free.FURUNO Authorized Distributor/DealerFURUNO Authorized Distributor/Dealer9-52 Ashihara-cho,9-52

Strany 36

IV INTRODUCTION Word to the Owner Thank you for purchasing this FURUNO Voyage Data Recorder. We are confident you will discover why FURUNO has bec

Strany 37

VSPECIFICATIONS Standards IMO A.861(20), IEC 61996, A.694, IEC 60945, IEC 61162, etc. Data collecting unit (DCU) .1 Structure of DCU Deck mounte

Strany 38

VI .3 Environmental tests for protective capsule Fire: 1100°C for 1 h, 260°C for 10 h (complies with ED 56A) Shock: 50 G, duration 11 ms Penetr

Strany 39

VIIMANUFACTURER’S DECLARATION Quality assurance Furuno Electric Co., Ltd. Markets a wide range of industrial equipment and systems for aviation ele

Strany 40 - VR-5000VR-5000

VIII SYSTEM CONFIGURATION 100-230 VAC Fig. A System Configuration of VR-5000 Environmental category DCU, RAP Protected from weathe

Komentáře k této Příručce

Žádné komentáře